{"id":39324,"date":"2025-12-02T22:22:10","date_gmt":"2025-12-02T21:22:10","guid":{"rendered":"https:\/\/rebotherm.de\/aerogel-floor-build-up\/"},"modified":"2026-04-12T18:37:43","modified_gmt":"2026-04-12T16:37:43","slug":"aerogel-floor-build-up","status":"publish","type":"page","link":"https:\/\/rebotherm.de\/en\/aerogel-floor-build-up\/","title":{"rendered":"Aerogel Floor Build-up"},"content":{"rendered":"<div class=\"et_d4_element et_pb_section et_pb_section_0  et_pb_css_mix_blend_mode et_section_regular et_block_section\" >\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_d4_element et_pb_row et_pb_row_0  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_0  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h1>Aerogel Floor Build-up \u2013 maximum insulation performance with minimal height<\/h1>\n<p>An<strong> Aerogel floor build-up<\/strong> offers one of the most efficient ways to achieve excellent insulation performance with minimal build-up height. Especially for renovations, old buildings, and refurbishments with limited space, an Aerogel floor build-up is ideally suited, as Aerogel enables outstanding thermal insulation despite extremely low material thickness. In combination with modern dry-system underfloor heating, an energy-efficient, durable, and stable floor build-up is created.  <\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_1  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_1  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>What is Aerogel Insulation and why is it ideal for flooring?<\/h2>\n<p>Aerogel is one of the world's most advanced and high-performance insulation materials. Due to its extremely low thermal conductivity (\u03bb \u2248 0.014\u20130.018 W\/mK), it is perfectly suited for <strong>low-profile floor build-ups<\/strong>. The insulation mats are flexible, highly effective, and moisture-repellent \u2013 ideal for renovations, old buildings, and energy modernizations.  <\/p>\n<ul>\n<li>extremely high insulation performance<\/li>\n<li>ideal for low build-up heights<\/li>\n<li>hydrophobic (does not absorb moisture)<\/li>\n<li>easy to process<\/li>\n<li>optimal complement to dry-system underfloor heating systems<\/li>\n<\/ul><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_2  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_2  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Aerogel insulation is not pressure-resistant \u2013 why this is important<\/h2>\n<p>For use under underfloor heating, it is crucial that <strong>Aerogel is not pressure-resistant<\/strong>. It exclusively performs the insulation function. To ensure the floor remains stable long-term, a <strong>pressure-stable, load-distributing layer<\/strong> must always be installed above the Aerogel.  <\/p>\n<p>Suitable layers include:<\/p>\n<ul>\n<li>Dry screed panels (e.g., Fermacell)<\/li>\n<li>OSB panels<\/li>\n<li>system-specific dry-system panels for underfloor heating<\/li>\n<\/ul>\n<p>This is the only way to ensure the load is evenly distributed and the floor remains permanently load-bearing.<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_3  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_3  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Layer Structure in Detail: This is what a modern Aerogel floor build-up looks like<\/h2><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_4  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_1_2 et_pb_column et_pb_column_4  et_pb_css_mix_blend_mode et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2><\/h2>\n<p>For use under a dry system, we recommend the following build-up:<\/p>\n<h2 data-start=\"491\" data-end=\"572\"><strong data-start=\"491\" data-end=\"530\">Flooring <\/strong>(vinyl, parquet, tile)<\/h2>\n<h2 data-start=\"573\" data-end=\"634\"><strong data-start=\"573\" data-end=\"592\">Leveling compound<\/strong><\/h2>\n<h2 data-start=\"635\" data-end=\"715\"><strong data-start=\"635\" data-end=\"673\">Carbon heating film <\/strong>(infrared heating)<\/h2>\n<h2 data-start=\"716\" data-end=\"789\"><strong data-start=\"716\" data-end=\"747\">Adhesive layer \/ Leveling compound<\/strong><\/h2>\n<h2 data-start=\"790\" data-end=\"882\"><strong data-start=\"790\" data-end=\"840\">Load-distributing layer <\/strong>(OSB \/ dry screed)<\/h2>\n<h2 data-start=\"883\" data-end=\"966\"><strong data-start=\"883\" data-end=\"924\">Aerogel insulation <\/strong>(single or double layer)<\/h2>\n<p data-start=\"967\" data-end=\"992\"><strong data-start=\"967\" data-end=\"992\">Subfloor \/ Substrate<\/strong><\/p>\n<p data-start=\"967\" data-end=\"992\"><strong data-start=\"967\" data-end=\"992\"><br \/><\/strong>This build-up ensures high energy efficiency, stability, and durability \u2013 even with extremely limited build-up height. The excellent insulation values prevent unwanted heat loss downwards, while the dry screed or OSB layer reliably distributes the load and optimally protects the carbon heating film. <\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div><div class=\"et_d4_element et_pb_column_1_2 et_pb_column et_pb_column_5  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_code et_pb_code_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_code_inner\"><svg  role=\"img\"  aria-label=\"Aerogel Fu\u00dfbodenaufbau \u2013 schematische Darstellung der Bodenschichten\"  xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  viewBox=\"0 0 800 900\"  width=\"100%\"  preserveAspectRatio=\"xMidYMid meet\"  style=\"display:block; width:100%; height:auto; margin:0 auto;\">\n  <style>\n    text {\n      font-family: Arial, system-ui, -apple-system, BlinkMacSystemFont, sans-serif;\n      font-size: 20px;\n      fill: #222;\n    }\n  <\/style>\n\n  <!-- Bodenbelag -->\n  <rect x=\"50\" y=\"40\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#f5f5f5\" stroke=\"#bdbdbd\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"95\">Flooring (vinyl, parquet, tile)<\/text>\n\n  <!-- Ausgleichsmasse -->\n  <rect x=\"50\" y=\"160\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#eeeeee\" stroke=\"#bdbdbd\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"215\">Leveling compound<\/text>\n\n  <!-- Carbon-Heizfolie -->\n  <rect x=\"50\" y=\"280\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#ffe0b2\" stroke=\"#ffb74d\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"335\">Carbon heating film (infrared heating)<\/text>\n\n  <!-- Kleberschicht \/ Spachtelung -->\n  <rect x=\"50\" y=\"400\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#e8f5e9\" stroke=\"#a5d6a7\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"455\">Adhesive layer \/ Leveling compound<\/text>\n\n  <!-- Lastverteilende Schicht -->\n  <rect x=\"50\" y=\"520\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#e3f2fd\" stroke=\"#90caf9\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"575\">Load-distributing layer (OSB \/ dry screed)<\/text>\n\n  <!-- Aerogel-D\u00e4mmung -->\n  <rect x=\"50\" y=\"640\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#ede7f6\" stroke=\"#b39ddb\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"695\">Aerogel insulation (1\u20132 layers)<\/text>\n\n  <!-- Rohdecke \/ Untergrund -->\n  <rect x=\"50\" y=\"760\" width=\"700\" height=\"90\" rx=\"12\" ry=\"12\" fill=\"#e0e0e0\" stroke=\"#9e9e9e\" stroke-width=\"2\"><\/rect>\n  <text x=\"70\" y=\"815\">Subfloor \/ Substrate<\/text>\n<\/svg>\n<\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_5  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_6  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_5  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Double Aerogel Insulation \u2013 more insulation performance in less space<\/h2>\n<p>A <strong>double-layer Aerogel insulation<\/strong> significantly increases the insulation effect without massively changing the floor height. The pressure resistance remains unchanged, therefore, the <strong>load-distributing layer remains absolutely essential<\/strong>. <\/p>\n<p>If very high insulation values are to be achieved, the use of two layers of Aerogel is often an ideal solution \u2013 especially for energy-efficient renovations and projects with strict requirements.  <a href=\"https:\/\/de.wikipedia.org\/wiki\/Aerogel\" target=\"_blank\" rel=\"nofollow noopener\">More information about Aerogel<\/a><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_6  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_7  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_6  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Is Aerogel insulation compatible with dry-system underfloor heating systems?<\/h2>\n<p>In most cases, the <strong>Aerogel floor build-up<\/strong> can be combined with common dry-system underfloor heating systems. It is important that the system panels: <\/p>\n<ul>\n<li>are pressure-stable and self-supporting<\/li>\n<li>distribute the load evenly<\/li>\n<li>completely cover the Aerogel insulation<\/li>\n<\/ul>\n<p>We would be happy to check whether the system you have planned or already have can be optimally combined with Aerogel.<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_7  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_8  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_7  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Your advantages with Aerogel in floor build-up<\/h2><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_8  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_1_2 et_pb_column et_pb_column_9  et_pb_css_mix_blend_mode et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_8  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><ul>\n<li>\u2714 excellent insulation values despite low build-up height<\/li>\n<li>\u2714 ideal for refurbishments and renovations<\/li>\n<li>\u2714 perfect for old buildings with limited space<\/li>\n<\/ul><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div><div class=\"et_d4_element et_pb_column_1_2 et_pb_column et_pb_column_10  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><ul>\n<li>\u2714 compatible with modern dry systems<\/li>\n<li>\u2714 durable, hydrophobic, and energy-efficient<\/li>\n<li>\u2714 ideal for heating systems with low flow temperature<\/li>\n<\/ul><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_9  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_11  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_10  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>Conclusion: Aerogel insulation is the best solution for thin floor build-ups<\/h2>\n<p><strong>Aerogel floor build-up<\/strong> offers a unique combination of extreme insulation performance, low thickness, and high compatibility with modern underfloor heating systems. For refurbishments, modernizations, and projects with limited height, Aerogel is the ideal solution \u2013 efficient, safe, and future-proof. <\/p>\n<p>We would be happy to advise you personally and create the suitable floor build-up for your project.<\/p><\/div>\n\t\t\t<\/div><div class=\"et_pb_button_module_wrapper et_pb_button_0_wrapper et_pb_button_alignment_center et_pb_module \">\n\t\t\t\t<a class=\"et_pb_button et_d4_element et_pb_button_0 et_pb_bg_layout_light et_block_module\" href=\"https:\/\/rebotherm.de\/en\/contact-us\/\">Get advice now<\/a>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div><div class=\"et_d4_element et_pb_row et_pb_row_10  et_pb_css_mix_blend_mode et_block_row\">\n\t\t\t\t<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_12  et_pb_css_mix_blend_mode et-last-child et_block_column\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_11  et_pb_text_align_left et_pb_bg_layout_light\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_text_inner\"><h2>FAQ \u2013 Frequently Asked Questions about Aerogel Floor Build-up<\/h2>\n<h3>Can I lay Aerogel directly under the flooring?<\/h3>\n<p>No. <strong>Aerogel must never be directly loaded<\/strong>. It exclusively performs the insulation function and must always be protected by a <g id=\"gid_1\">pressure-stable, load-distributing layer<\/g> (e.g., dry screed or OSB). Only above that follow the dry system, underfloor heating, and flooring.  <\/p>\n<h3>Is Aerogel insulation suitable for renovations with low build-up height?<\/h3>\n<p>Yes, Aerogel is ideal for exactly that. Due to its extremely low thermal conductivity, you achieve very high insulation performance with minimal thickness. Especially for existing building renovations where doors, stairs, or room heights are limited, <strong>Aerogel insulation in the floor build-up<\/strong> is a perfect solution.  <\/p>\n<h3>Can I install double-layer Aerogel insulation under underfloor heating?<\/h3>\n<p>Yes, a double layer is possible and significantly increases the insulation effect. However, it is important: The pressure resistance does not increase as a result. The <strong>load-distributing layer remains absolutely essential<\/strong> for the floor build-up to remain permanently stable.  <\/p>\n<h3>Does Aerogel insulation work with every dry system for underfloor heating?<\/h3>\n<p>Generally, Aerogel can be combined with most dry systems, provided the system panels are pressure-stable and distribute the load evenly. We recommend briefly checking compatibility \u2013 we would be happy to assist you and evaluate your specific floor build-up. <\/p>\n<h3>Is Aerogel insulation sensitive to moisture?<\/h3>\n<p>No. Aerogel is hydrophobic and does not absorb moisture. Nevertheless, the insulation must be professionally installed and protected against mechanical stress. In typical floor build-ups, Aerogel is completely enclosed by other layers.   <\/p>\n<h3>Can I save energy and heating costs with Aerogel insulation?<\/h3>\n<p>Yes. Due to its high insulation performance, <g id=\"gid_0\">Aerogel insulation in the floor build-up<\/g> significantly reduces heat loss. In combination with a dry-system underfloor heating, the flow temperature can often be lowered, which long-term leads to lower heating costs and higher efficiency.  <\/p>\n<h3>For which projects is Aerogel insulation particularly suitable?<\/h3>\n<p>Aerogel is particularly suitable for <strong>renovations, old buildings, and projects with low build-up height<\/strong>, for example, in the modernization of apartments, single-family homes, attics, or commercially used areas where every millimeter of floor height counts.<\/p><\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-39324","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/pages\/39324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/comments?post=39324"}],"version-history":[{"count":0,"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/pages\/39324\/revisions"}],"wp:attachment":[{"href":"https:\/\/rebotherm.de\/en\/wp-json\/wp\/v2\/media?parent=39324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}